MODBUS TRAFFIC TRANSPORT SYSTEM VIA LORAWAN

MODBUS TRAFFIC TRANSPORT SYSTEM VIA LORAWAN – COMPONENTS AND FUNCTIONALITIES

 

Device for optimized transport of Modbus TCP traffic via a LoRaWAN network

Main characteristics:

  • 1 Ethernet port 10/100Mbps
  • It is a terminal LoRaWAN terminal device
  • Compatible with DIN rail case
  • 1 hour autonomy
  • Data cache and compression

Application Server – software module installed in the client’s IP central network

Main characteristics:

  • Modbus slave behavior
  • Takes over Modbus TCP requests from Modbus Master applications
  • Integration with SCADA applications
Modbus peste LoRaWAN

MAI MULTE DETALII



    SPECIFIC BENEFITS OF MODBUS TRAFFIC TRANSPORT SYSTEM VIA LORAWAN


    • Transmission with confirmation of receipt and retransmission
    • Maximum speed available in LoRaWAN (transmission with LoRaWAN Datarate 5 and reception with Datarate 3)
    • Data compression to reduce time of answer (reading of 125 Modbus registries in 10-60 seconds)
    • Fragmentation and reassembly (if the length of a Modbus package with 125 registers exceeds the maximum length of a LoRaWAN data package)
    • Minimization of the LoRaWAN downlink emission time (Transfer rate Downlink LoRaWAN Datarate 3, 8 times higher than the implicit LoRaWAN rate Datarate 0)

    OTHER TECHNICAL CHARACTERISTICS


    • 1000m, maximum distance covered under conditions of direct visibility between the device and the LoRa gateway
    • External supply at 9-14Vcc, 1 hour autonomy with internal accumulator

    INTEGRATION IN SCADA ENVIRONMENT


    The Modbus traffic transport solution via LoRaWAN may be integrated with a SCADA system by adding a DNP3 device/Modbus gateway between the client’s SCADA application and the Application server module.



    The gateway is seen by the SCADA application as DNP3 outstation and acts as a Modbus master to the Application server. A translation table is configured in the device, with associations of DNP3 and Modbus commands.

    The gateway periodically reads data through Modbus from the Application server. The client’s SCADA DNP3 server application transmits its requests to the gateway with a DNP3 outstation role and immediately receives answers from it, containing the most recent values read by the gateway through Modbus.

    When the gateway receives writing commands from the DNP3 server, it transmits Modbus TCP commands to the Application server, according to the configuration in its DNP3-Modbus translation table.

    TURN KEY PROJECTS OFFERED BY DATANET


    Datanet ensures the following services:

    • design of the Modbus communication system via LoRAWAN;
    • delivery, installation and reintegration of devices and the Application server;
    • full training, service and technical support services.